Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 782
Filtrar
1.
Curr Probl Dermatol ; 55: 157-169, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34698042

RESUMO

In 1978, the FDA Advisory Panel proposed both indoor and natural sunlight SPF testing methods but reverted to indoor testing only in 1993. Today's sunscreen sun protection and broad-spectrum claims are based on mandated clinical tests using solar simulators and in vitro spectrophotometers. This research evaluated the protection of 10 high-SPF (30-110), broad-spectrum sunscreen products, as well as 6 sun-protective fabrics against natural sunlight in Arequipa, Peru. Each of the 17 subjects was exposed to natural sunlight for 1 h and 59 min under clear skies, with temperatures and humidity similar to those in an indoor clinical laboratory. Test sites were photographed 16-24 h later. Four dermatologists evaluated the photographs for erythema and persistent pigment darkening (PPD). Perceptible sun-induced skin injury (sunburn and/or pigmentation) was detected at 97% of the sunscreen-protected scores. The most sun-sensitive subjects obtained the least erythema protection. The higher the SPF was, the higher the erythema protection, but the intensity of PPD was also higher. The 2 sunscreens using only FDA-approved sunscreen filters rated 30 SPF and 45+ SPF performed poorly: Eighty-one percent of the 136 scores were graded 1 minimal erythema dose or higher erythema, achieving, at a maximum, SPF of 5-7 in natural sunlight. Sun-protective fabrics tested provided excellent sun protection. The erythema and PPD observed through the sunscreens in less than 2 h are incongruous with the broad-spectrum, high-SPF sunscreen claims. Reapplying these sunscreens and staying in the sun longer, as stated on the product labels, would have subjected the subjects to even more UV exposure. High-SPF, broad-spectrum sunscreen claims based on indoor solar simulator testing do not agree with the natural sunlight protection test results.


Assuntos
Roupa de Proteção/normas , Fator de Proteção Solar/métodos , Luz Solar/efeitos adversos , Protetores Solares/química , Têxteis/normas , Avaliação Pré-Clínica de Medicamentos/métodos , Avaliação Pré-Clínica de Medicamentos/normas , Eritema/etiologia , Eritema/prevenção & controle , Feminino , Voluntários Saudáveis , Humanos , Masculino , Peru , Pele/efeitos dos fármacos , Pele/efeitos da radiação , Pigmentação da Pele/efeitos dos fármacos , Pigmentação da Pele/efeitos da radiação , Fator de Proteção Solar/normas , Protetores Solares/administração & dosagem , Protetores Solares/normas
3.
BMJ Mil Health ; 167(3): 163-167, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32086264

RESUMO

INTRODUCTION: Severe haemorrhage from the arm that is unresponsive to direct pressure necessitates the application of a tourniquet. Detachable arm protection, referred to as brassards, are used by the UK Armed Forces to protect the upper arm from fragmentation threats. However, the coverage they originally provided was based on limited medical evidence. Medical consensus has determined that the dimensions of arm protection should in future be related to how far up the arm a tourniquet can be applied. METHOD: CT scans of 120 male Armed Forces personnel were analysed to ascertain the vertical distances from acromion process to the point at which a tourniquet can applied, equating to the anterior axillary fold. These values were statistically compared with those derived from the 2007 UK Military anthropometric survey using a paired t-test. Additional distances were added to account for tourniquet width and slippage, with the total value compared with VIRTUS brassard length. RESULTS: No significant difference (p<0.01) was found in mean acromion to axilla length (114 mm) compared with that found in the anthropometric survey confirming sample validity. The deltoid insertion lay 24 mm below the axillary fold for the 50th percentile value from CT. Essential arm coverage for the 99th percentile male in this study was calculated as 201 mm. CONCLUSIONS: Based on this research, a single new brassard for the VIRTUS body armour and load carriage system was recommended and manufactured based on the 99th percentile. This is over 30% shorter than the existing VIRTUS brassard, reducing the overall weight burden for the soldier and improving heat dispersion, integration and interoperability. The new brassard has been issued to Armed Forces personnel since October 2018. The reduced mass of ballistic protective material in conjunction with requiring only a single size of brassard has already saved the Ministry of Defence £20 000 in procurement costs.


Assuntos
Tamanho Corporal , Roupa de Proteção/normas , Extremidade Superior/fisiologia , Adulto , Antropometria/métodos , Desenho de Equipamento/métodos , Humanos , Modelos Lineares , Masculino , Roupa de Proteção/estatística & dados numéricos , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Reino Unido
4.
BMJ Mil Health ; 167(3): 147-152, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32094217

RESUMO

INTRODUCTION: Side plates are worn by UK Armed Forces as part of the VIRTUS body armour and load carriage systems to protect the thorax and abdomen from high-velocity threats. The VIRTUS project has provided the impetus to objectively demonstrate the anatomical coverage provided by side plates. METHOD: CT scans of 120 male UK Armed Forces personnel were analysed to ascertain the vertical distance between the anterior axillary fold and iliac crest, and horizontal distance between anterior and posterior borders of the liver, delineating the boundaries of essential medical coverage from the side aspects. The percentage of shot-lines intersected by the existing Enhanced Combat Body Armour (ECBA) plates as well as an optimised plate based on the maximum potential dimensions of essential coverage was determined in the Coverage of Armour Tool. RESULTS: ECBA plates were 101 mm shorter and 4 mm narrower than a plate with dimensions providing essential medical coverage for the 50th percentile subject (157×315 mm). Coverage increased by 35% when using two ECBA plates as side coverage in addition to using the front and rear OSPREY plates in the VIRTUS vest. Two side plates with dimensions providing essential medical coverage for the 50th percentile increased anatomical coverage by a further 16%. CONCLUSIONS: This analysis has provided strong evidence that ECBA plates are already optimised for side protection, despite not being originally designed for this purpose. They are correctly positioned within the VIRTUS soft body armour vest and the width of the ECBA plate is only 3% less than what would be optimum size for the 50th percentile. Although the height of the plate could be increased to further enhance the anatomical coverage, it is unlikely that this would be acceptable in terms of the human factors, equipment integration or additional mass.


Assuntos
Axila/lesões , Desenho de Equipamento/métodos , Roupa de Proteção/tendências , Traumatismos Torácicos/prevenção & controle , Traumatismos por Explosões/prevenção & controle , Desenho de Equipamento/normas , Humanos , Roupa de Proteção/normas , Roupa de Proteção/provisão & distribuição , Traumatismos Torácicos/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Ferimentos por Arma de Fogo/prevenção & controle
5.
Oncologist ; 26(2): e336-e337, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33044758

RESUMO

The novel coronavirus disease 2019 has grown to be a global public health emergency. The rapid spread of the infection has raised many questions in the oncohematological scientific community regarding the appropriateness of high-dose chemotherapy with autologous stem cell transplantation (ASCT). We here report two cases of patients who received ASCT at our Institute during the epidemic in Italy, affected with Hodgkin lymphoma and germ cell tumor, respectively. The two patients underwent a nasopharyngeal swab for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) on hospital admittance and during the period of bone marrow aplasia. They were attended to exclusively by dedicated health care staff who followed specifically implemented protocols for bedside nursing and care. They completed the procedure without unexpected side effect. Our experience demonstrates how ASCT can be performed safely if procedures are reorganized ad hoc to reduce the risk of SARS-CoV-2 infection.


Assuntos
COVID-19/prevenção & controle , Tumor do Seio Endodérmico/terapia , Transplante de Células-Tronco Hematopoéticas/normas , Doença de Hodgkin/terapia , Controle de Infecções/normas , Adolescente , Adulto , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/transmissão , Teste para COVID-19/normas , Feminino , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Doença de Hodgkin/diagnóstico , Doença de Hodgkin/imunologia , Humanos , Masculino , Pandemias/prevenção & controle , Roupa de Proteção/normas , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , Condicionamento Pré-Transplante/efeitos adversos , Condicionamento Pré-Transplante/normas , Transplante Autólogo/normas , Resultado do Tratamento
6.
Ind Health ; 59(1): 27-33, 2021 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-33191316

RESUMO

This study aimed to validate the summation methods suggested by ISO 9920. Twenty seven items from an ambulance personnel clothing system were selected for testing. The basic insulation of each garment item (Iclu) was calculated based on the thermal manikin tests. More than 100 realistic clothing combinations were compiled and basic insulation (Icl) of these ensembles was calculated according to ISO 9920. These were ranked after the calculated insulation, and 14 sets covering insulation from 0.63 to 3.33 clo were measured on the thermal manikin for acquiring the basic clothing insulation (Icl). Regression analysis was used to compare the summed and measured Icl values. The difference between values varied from -18 to 12%. The highest percentual difference was for the lightest clothing sets, while the absolute differences were similar over the whole insulation range ranging between -0.17 to 0.18 clo with an average difference of 0.02 clo (-0.16%). All basic insulation values stayed very close to the line of identity (R2=0.98). The summation equation gave, in the case of this ambulance clothing system, very close results to the measured values. This encourages evaluating and selecting protective clothing combinations for thermal comfort based on individual item measurements.


Assuntos
Roupa de Proteção/classificação , Ambulâncias , Socorristas , Manequins , Roupa de Proteção/normas
7.
Workplace Health Saf ; 69(7): 315-322, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33357122

RESUMO

BACKGROUND: Adverse health effects among agricultural workers due to chronic heat exposure have been characterized in the literature as not only due to high ambient temperatures but also due to intensive manual labor in hot and humid conditions. The aim of this study was to use biomonitoring equipment to examine the effectiveness of selected cooling devices at preventing agricultural workers from exceeding the core body temperature threshold of 38.0°C (Tc38) and attenuating heat-related illness symptoms. METHODS: A convenience sample of 84 agricultural workers in Florida was randomized to one of four groups: (a) no intervention, clothing as usual; (b) cooling bandana; (c) cooling vest; and (d) both the cooling bandana and cooling vest. Biomonitoring equipment worn by the participants included core body temperature monitor and an accelerometer to capture physical activity. FINDINGS: A total of 78 agricultural workers completed one intervention workday trial. Compared with the control group, the bandana group had lower odds of exceeding Tc38 (odds ratio [OR] = 0.7, 90% confidence interval [CI] = [0.2, 3.2]) and the vest group had higher odds of exceeding Tc38 (OR = 1.8, 90% CI = [0.4, 7.9]). The simultaneous use of cooling vest and bandana showed an effect little different from the control group (OR = 1.3, 90% CI = [0.3, 5.6]). CONCLUSION/APPLICATION TO PRACTICE: This is the first field-based study to examine cooling intervention among agricultural workers in the United States using biomonitoring equipment. This study found that using a bandana while working in a hot agricultural environment has the potential to be protective against exceeding the recommended Tc38 threshold.


Assuntos
Fazendeiros/estatística & dados numéricos , Transtornos de Estresse por Calor/diagnóstico , Temperatura Alta/efeitos adversos , Adulto , Temperatura Corporal/fisiologia , Regulação da Temperatura Corporal/fisiologia , Fazendas/organização & administração , Fazendas/estatística & dados numéricos , Feminino , Florida/epidemiologia , Transtornos de Estresse por Calor/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismos Ocupacionais/diagnóstico , Traumatismos Ocupacionais/epidemiologia , Projetos Piloto , Roupa de Proteção/normas , Roupa de Proteção/estatística & dados numéricos
8.
Dermatol Surg ; 46(12): 1676-1682, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33165083

RESUMO

BACKGROUND: Laser procedures are becoming more prevalent across multiple medical specialties for a variety of indications. The plumes created by these lasers have raised concern for the dissemination of an infectious material. OBJECTIVE: To review and summarize the information on viral dissemination in laser plumes available in the literature. MATERIALS AND METHODS: Data Sources A systematic review was performed on English and non-English articles using the PubMed and the Cochrane databases. A manual search of bibliographies from relevant articles was also performed to collect additional studies. STUDY SELECTION: Only articles in the English language with full texts available that pertained to viral particles in laser plumes were included. Data Extraction Two authors performed independent article selections using predefined inclusion and exclusion criteria. RESULTS: There have been case reports of possible transmission of human papillomavirus (HPV) by inhalation of laser-produced aerosols. Multiple investigators have attempted to recreate this scenario in the laboratory to qualify this risk. Others have conducted clinical experiments to determine the presence of HPV in laser plumes. CONCLUSION: The current body of the literature suggests that laser surgeons are at a risk for HPV exposure by inhalation of laser-derived aerosols. We offer best practice recommendations for laser operators.


Assuntos
Aerossóis/efeitos adversos , Terapia a Laser/efeitos adversos , Doenças Profissionais/prevenção & controle , Exposição Ocupacional/efeitos adversos , Infecções por Papillomavirus/transmissão , Alphapapillomavirus/patogenicidade , Dermatologistas/normas , Dermatologistas/estatística & dados numéricos , Neoplasias de Cabeça e Pescoço/epidemiologia , Neoplasias de Cabeça e Pescoço/prevenção & controle , Neoplasias de Cabeça e Pescoço/virologia , Humanos , Incidência , Exposição por Inalação/efeitos adversos , Exposição por Inalação/normas , Exposição por Inalação/estatística & dados numéricos , Doenças da Laringe/epidemiologia , Doenças da Laringe/prevenção & controle , Doenças da Laringe/virologia , Terapia a Laser/normas , Terapia a Laser/estatística & dados numéricos , Máscaras/normas , Doenças Profissionais/epidemiologia , Doenças Profissionais/virologia , Exposição Ocupacional/estatística & dados numéricos , Infecções por Papillomavirus/epidemiologia , Infecções por Papillomavirus/cirurgia , Infecções por Papillomavirus/virologia , Guias de Prática Clínica como Assunto , Roupa de Proteção/normas , Pele/efeitos da radiação , Pele/virologia , Neoplasias Cutâneas/cirurgia , Neoplasias Cutâneas/virologia , Carcinoma de Células Escamosas de Cabeça e Pescoço/epidemiologia , Carcinoma de Células Escamosas de Cabeça e Pescoço/prevenção & controle , Carcinoma de Células Escamosas de Cabeça e Pescoço/virologia , Cirurgiões/normas , Cirurgiões/estatística & dados numéricos
9.
J Therm Biol ; 93: 102703, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33077124

RESUMO

The purpose of the present study was to evaluate the effectiveness of passive and post-exercise heat acclimation strategies through directly heating the skin with a water-perfused suit. Nineteen young males participated in the heat acclimation (HA) protocols for 10 days, which were conducted at an air temperature of 33oC with 60%RH. The exercise-only condition (N = 6) conducted 1-h treadmill walking (6 km·h-1) followed by 1-h rest. The post-exercise passive-heating condition (N = 6) wore the suit (inflow water temperature 44.2oC) for 1-h after 1-h walking. The passive-heating condition (N = 7) donned the suit for 2 h. Heat tolerance tests (leg immersion in 42oC water for 60 min) were conducted before and after the training to evaluate changes due to the 10-day intervention. Reflecting that suit-wearing for 10 days as both passive and post-exercise HA strategies can effectively induce adaptive changes, significant interaction effects appeared in: increase or decrease in mean skin temperature (P < 0.05) and elevation in whole-body sweat rate (P < 0.05). Reduction in rectal temperature (P < 0.05) and blood pressure (P < 0.05) were found most prominently in the passive-heating condition. These results indicate that this new method of heat acclimation training, donning a skin-heating water-perfused suit, can generate thermoregulatory benefits. The passive HA intervention could be applied to individuals for whom doing exercise regularly are not feasible.


Assuntos
Hipertermia Induzida/métodos , Condicionamento Físico Humano/métodos , Roupa de Proteção/normas , Temperatura Cutânea , Termotolerância , Pressão Sanguínea , Temperatura Alta , Humanos , Umidade , Hipertermia Induzida/instrumentação , Masculino , Condicionamento Físico Humano/instrumentação , Roupa de Proteção/efeitos adversos , Adulto Jovem
10.
BMJ Open Qual ; 9(3)2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32978176

RESUMO

INTRODUCTION: Effective implementation of standard precautions specific to COVID-19 is a challenge for hospitals within the existing constraints of time and resources. AIM: To rapidly design and operationalise personal protective equipment (PPE) donning and doffing areas required for a COVID-19 care facility. METHODS: Literature review was done to identify all issues pertaining to donning and doffing in terms of Donabedian's structure, process and outcome. Training on donning and doffing was given to hospital staff. Donning and doffing mock drills were held. 5S was used as a tool to set up donning and doffing areas. Instances of donning and doffing were observed for protocol deviations and errors. Plan-do-study-act cycles were conducted every alternate day for 4 weeks. The initiative was reported using Standards for QUality Improvement Reporting Excellence (SQUIRE) guidelines. RESULTS: Best practices in donning and doffing were described. Our study recommends a minimum area of 16 m2 each for donning and doffing rooms. Verbally assisted doffing was found most useful than visual prompts. DISCUSSION: Challenges included sustaining the structure and process of donning and doffing, varied supplies of PPE which altered sequencing of donning and/or doffing, and training non-healthcare workers such as plumbers, electricians and drivers who were required during emergencies in the facility. CONCLUSION: Our study used evidence-based literature and quality improvement (QI) tools to design and operationalise donning and doffing areas with focus on people, task and environment. Our QI will enable healthcare facilities to rapidly prototype donning and doffing areas in a systematic way.


Assuntos
Infecções por Coronavirus/prevenção & controle , Pessoal de Saúde/organização & administração , Controle de Infecções/normas , Saúde Ocupacional/normas , Pandemias/prevenção & controle , Equipamento de Proteção Individual/normas , Pneumonia Viral/prevenção & controle , Adulto , Betacoronavirus , COVID-19 , Infecções por Coronavirus/transmissão , Feminino , Pessoal de Saúde/normas , Implementação de Plano de Saúde , Humanos , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Masculino , Pessoa de Meia-Idade , Pneumonia Viral/transmissão , Roupa de Proteção/normas , Melhoria de Qualidade , Dispositivos de Proteção Respiratória/normas , SARS-CoV-2 , Adulto Jovem
11.
J Bras Nefrol ; 42(2 suppl 1): 9-11, 2020 Aug 26.
Artigo em Inglês, Português | MEDLINE | ID: mdl-32877491

RESUMO

These recommendations were created after the publication of informative note 3/2020- CGGAP/DESF/SAPS/MS, of April 4, 2020, in which the Brazilian Ministry of Health recommended the use of a cloth mask by the population, in public places. Taking into account the necessary prioritization of the provision of Personal Protective Equipment (PPE) for patients with suspected or confirmed disease, as well as for healthcare professionals, the SBN is favorable concerning the wear of cloth masks by chronic kidney patients in dialysis, in public settings, except in the dialysis setting. The present recommendations have eleven items, related to this rationale, the procedures, indications, contraindications, as well as appropriate fabrics for the mask, and hygiene care to be adopted. These recommendations may change, at any time, in the light of new evidence.


Assuntos
Betacoronavirus , Infecções por Coronavirus/prevenção & controle , Máscaras/normas , Pandemias/prevenção & controle , Equipamento de Proteção Individual/normas , Pneumonia Viral/prevenção & controle , Diálise Renal , Têxteis , Brasil , COVID-19 , Infecções por Coronavirus/epidemiologia , Pessoal de Saúde , Humanos , Nefrologia/normas , Doenças Profissionais/prevenção & controle , Pneumonia Viral/epidemiologia , Roupa de Proteção/normas , Insuficiência Renal Crônica/terapia , SARS-CoV-2 , Sociedades Médicas , Unidade Hospitalar de Urologia/normas
12.
J Hosp Infect ; 106(3): 605-609, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32745589

RESUMO

At the peak of the coronavirus disease 2019 (COVID-19) pandemic, hand hygiene audits indicated decreased compliance in a 12-bed critical care (CC) area with ventilated COVID-19 patients, where staff used personal protective equipment (PPE), including sessional use of long-sleeved gowns in accordance with the recommendations of Public Health England. There was also a cluster of three central venous catheter (CVC) infections along with increases in the number of patients from whom enteric Gram-negative bacteria (GNB) were isolated from sterile sites. Environmental sampling of near-patient surfaces and frequently touched sites demonstrated that 11.5% of areas were contaminated with enteric GNB in the COVID-19 CC area, compared with 2.6% and 2.7% in COVID-19 and non-COVID-19 general wards, respectively. Following a risk assessment, hospital policy was changed to replace long-sleeved gowns with short-sleeved gowns. The CC unit underwent enhanced cleaning with hypochlorite-based disinfectant and was resampled 8 days later. On resampling, no GNB were isolated from the CC unit. Following this change in PPE, hand hygiene compliance returned to baseline standards and no further CVC infections were identified. Staff reported a preference for short-sleeved gowns. No evidence currently exists that PPE beyond that recommended for pandemic influenza (respiratory protection plus standard PPE) adds to the protection of healthcare workers (HCWs) from severe acute respiratory syndrome coronavirus-2. Long-sleeved gowns prevent HCWs performing hand hygiene effectively. While it is imperative that HCWs are adequately protected, protection of patients from infection hazards is equally important. Further studies are necessary to establish risks from PPE to inform a review of current guidance.


Assuntos
Infecções por Coronavirus/prevenção & controle , Cuidados Críticos/normas , Guias como Assunto , Transmissão de Doença Infecciosa do Profissional para o Paciente/prevenção & controle , Pandemias/prevenção & controle , Equipamento de Proteção Individual/normas , Pneumonia Viral/prevenção & controle , Roupa de Proteção/normas , Vestimenta Cirúrgica/virologia , Betacoronavirus , COVID-19 , Inglaterra , Humanos , SARS-CoV-2
13.
Med Leg J ; 88(1_suppl): 47-49, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32686980

RESUMO

In the context of Covid-19, personal protective equipment is much needed and often in short supply as a protection against the virus, but nobody until recently was discussing the downside of its prolonged use by its wearers. Increasing numbers of health care workers feel unwell using it and are overheating and some have fainted. Will it impair their professional performance? This article considers this aspect of PPE based upon the personal experience of a Forensic team at AIIMS Bhopal in India who wore it during autopsy work and proposed recommendations to minimise it.


Assuntos
Betacoronavirus , Infecções por Coronavirus/prevenção & controle , Pandemias/prevenção & controle , Equipamento de Proteção Individual/normas , Pneumonia Viral/prevenção & controle , Carga de Trabalho/normas , Temperatura Corporal , COVID-19 , Pessoal de Saúde/estatística & dados numéricos , Humanos , Índia , Equipamento de Proteção Individual/efeitos adversos , Roupa de Proteção/normas , SARS-CoV-2
14.
Int J Legal Med ; 134(5): 1949-1956, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32691137

RESUMO

One type of clothing system used in the English Civil War, more common amongst cavalrymen than infantrymen, was the linen shirt, wool waistcoat and buff-coat. Ballistic testing was conducted to estimate the velocity at which 50% of 12-bore lead spherical projectiles (V50) would be expected to perforate this clothing system when mounted on gelatine (a tissue simulant used in wound ballistic studies). An estimated six-shot V50 for the clothing system was calculated as 102 m/s. The distance at which the projectile would have decelerated from the muzzle of the weapon to this velocity in free flight was triple the recognised effective range of weapons of the era suggesting that the clothing system would provide limited protection for the wearer. The estimated V50 was also compared with recorded bounce-and-roll data; this suggested that the clothing system could provide some protection to the wearer from ricochets. Finally, potential wounding behind the clothing system was investigated; the results compared favourably with seventeenth century medical writings.


Assuntos
Conflitos Armados/história , Vestuário/história , Armas de Fogo/história , Balística Forense , Roupa de Proteção/história , Vestuário/normas , Inglaterra , História do Século XVII , Humanos , Masculino , Roupa de Proteção/normas
15.
J Therm Biol ; 91: 102634, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32716876

RESUMO

Persons with paraplegia (PA) from thoracic spinal cord injury (T1-T12) are prone to thermal stress during exercise due to impaired thermoregulation. This study evaluates the effectiveness of phase change material (PCM) cooling vests on persons with PA of different levels of injury during exercise in hot exposure. Sixteen participants were recruited and divided to three groups based on injury level; high-thoracic T1-T3, mid-thoracic T4-T8, and low thoracic T9-T12 to perform a 30-min arm-crank exercise at a 30 °C room condition. Two types of PCM vests at melting temperature of 20 °C were tested: i) V1 with PCM covering the trunk of 3.4 kg overall vest mass and ii) V2 with PCM covering chest and upper back of 2.17 kg overall vest mass. High thoracic and low-thoracic groups performed NV and V1 tests; whereas, mid-thoracic group performed NV, V1, and V2 tests. Heart rate, core, and skin temperatures were monitored during 15-min preconditioning, 30-min exercise, and 15-min recovery. In addition, thermal comfort, sensation, skin wettedness, and perceived exertion were recorded during exercise only. The main findings were that the effectiveness of the cooling vest was dependent on injury level and portion of sensate skin of trunk covered by the PCM packets. Rise in core temperature (ΔTcr) was reduced significantly for the low-thoracic group during exercise and recovery (ΔTcr=0.41°C, 0.26°C for NV and V1; respectively, p<0.05). For the mid-thoracic group, both V1 (p = 0.001) and V2 (p = 0.008) were effective in reducing ΔTcr compared to the NV test at the end of the recovery period (0.74°C,0.42°C,0.56°C, for NV, V1 and V2; respectively). For the high-thoracic group, V1 was not effective in reducing core temperature (p>0.05). For the mid-thoracic group, V2 at 36% lower mass significantly improved thermal comfort (p = 0.0004) compared to the NV test and was as effective compared to V1 in reducing core temperature.


Assuntos
Temperatura Corporal , Paraplegia/fisiopatologia , Roupa de Proteção/normas , Traumatismos da Medula Espinal/fisiopatologia , Adulto , Exercício Físico , Feminino , Frequência Cardíaca , Temperatura Alta , Humanos , Masculino , Vértebras Torácicas/lesões
16.
Neurogastroenterol Motil ; 32(7): e13930, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32525249

RESUMO

BACKGROUND: During the peak of the COronaVIrus Disease 2019 (COVID-19) pandemic, care for patients with gastrointestinal motility and functional disorders was largely suspended. In the recovery phases of the pandemic, non-urgent medical care is resumed, but there is a lack of guidance for restarting and safely conducting motility and function testing. Breath tests and insertion of manometry and pH-monitoring probes carry a risk of SARS-CoV-2 spread through droplet formation. METHODS: A panel of experts from the European Society for Neurogastroenterology and Motility (ESNM) evaluated emerging national and single-center recommendations to provide the best current evidence and a pragmatic approach to ensure the safe conduct of motility and function testing for both healthcare professionals and patients. RESULTS: At a general level, this involves evaluation of the urgency of the procedure, evaluation of the infectious risk associated with the patient, the investigation and the healthcare professional(s) involved, provision of the test planning and test units, education and training of staff, and use of personnel protection equipment. Additional guidance is provided for specific procedures such as esophageal manometry, pH monitoring, and breath tests. CONCLUSIONS AND INFERENCES: The ESNM guidelines provide pragmatic and appropriate guidance for the safe conduct of motility and function testing in the COVID-19 pandemic and early recovery phase.


Assuntos
Betacoronavirus , Infecções por Coronavirus/epidemiologia , Gastroenterologia/normas , Motilidade Gastrointestinal/fisiologia , Neurologia/normas , Pneumonia Viral/epidemiologia , Guias de Prática Clínica como Assunto/normas , Recuperação de Função Fisiológica/fisiologia , COVID-19 , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/terapia , Europa (Continente)/epidemiologia , Prova Pericial/métodos , Prova Pericial/normas , Pessoal de Saúde/normas , Humanos , Pandemias/prevenção & controle , Pneumonia Viral/diagnóstico , Pneumonia Viral/terapia , Roupa de Proteção/normas , SARS-CoV-2 , Sociedades Médicas/normas
17.
Neurogastroenterol Motil ; 32(7): e13926, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32478910

RESUMO

BACKGROUND: The COVID-19 pandemic, declared by WHO on March 13, 2020, had a major global impact on the healthcare system and services. In the acute phase, the presence of the SARS-CoV-2 virus in the aerodigestive tract limited activities in the gastroenterology clinic and procedures to emergencies only. Motility and function testing was interrupted and as we enter the recovery phase, restarting these procedures requires a safety-focused approach with adequate infection prevention for patients and healthcare professionals. METHODS: We summarized knowledge on the presence of the SARS-CoV-2 virus in the aerodigestive tract and the risk of spread with motility and functional testing. We surveyed 39 European centers documenting how the pandemic affected activities and which measures they are considering for restarting these measurements. We propose recommendations based on current knowledge as applied in our center. RESULTS: Positioning of catheters for gastrointestinal motility tests carries a concern for aerosol-borne infection of healthcare workers. The risk is low with breath tests. The surveyed centers stopped almost all motility and function tests from the second half of March. The speed of restarting and the safety measures taken varied highly. CONCLUSIONS AND INFERENCES: Based on these findings, we provided recommendations and practical relevant information for motility and function test procedures in the COVID-19 pandemic era, to guarantee a high-quality patient care with adequate infection prevention.


Assuntos
Betacoronavirus , Infecções por Coronavirus/epidemiologia , Gastroenterologia/métodos , Motilidade Gastrointestinal/fisiologia , Pandemias , Pneumonia Viral/epidemiologia , Recuperação de Função Fisiológica/fisiologia , COVID-19 , Infecções por Coronavirus/prevenção & controle , Europa (Continente)/epidemiologia , Gastroenterologia/normas , Pessoal de Saúde/normas , Humanos , Pandemias/prevenção & controle , Assistência ao Paciente/métodos , Assistência ao Paciente/normas , Pneumonia Viral/prevenção & controle , Guias de Prática Clínica como Assunto/normas , Roupa de Proteção/normas , SARS-CoV-2 , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...